A Comparative Confocal Microscopy Analysis After LASIK With the IntraLase Femtosecond Laser vs Hansatome Microkeratome

Manuel Ramírez, Everardo Hernández-Quíntela, Ramón Naranjo-Tackman

Journal of Refractive Surgery · 2007 · 24 citations · 8 references

Concepts

Abstract

PURPOSE: To evaluate and compare confocal microscopy findings between a femtosecond laser and a mechanical microkeratome. METHODS: Eighteen eyes of nine patients underwent LASIK. Corneal flaps were created with the femtosecond laser in the right eyes and a mechanical microkeratome in the left eyes. The corneal flap interface was analyzed in all eyes with a confocal microscope at 1 week and 1 month postoperatively. RESULTS: All eyes showed small reflective particles at the corneal flap interface. The mean number of reflective particles was not statistically significantly different at 1 week (P = .078) and 1 month (P = .28) using a femtosecond laser and a mechanical microkeratome. CONCLUSIONS: Confocal microscopy findings at the corneal flap interface showed a similar number of particles using both systems.

References

8