Archives of Environmental Health An International Journal · 1972 · 26 citations · 6 references
Life SciencesEnvironmental SciencesMicrobiologyAtmospheric RadiationMedical MicrobiologyVentilationAir MicrobiologyAir QualityEnvironmental DisinfectionUltraviolet Radiation ProtectionAerosolized DisinfectionAir DisinfectionBiological AerosolsIndoor Air MicrobiologyLampsUltraviolet DisinfectionViable Cell CountViable Cell Counting
Abstract Studies of the efectiveness of upper air ultra violet (UV) radiation against artificially generated bacterial aerosols were conducted in a laboratory test room with an 8 foot 6 Inch ceiling; the room was ventilated with six air changes per hour (ch/hr). At or below the five-foot level in the room, reflected UV radiation ranged from 0.02; to 2.6μw/sq cm, in the upper portion of the room, direct UV radiation ranged from about 10 to 150μw/sq cm. The test organism was late-log-phase Serratia marcescens in aerosols with single viable cells per particle; count median diameters (CMD) of 2.7μ and 5.2μ were generated With the 2.7μ and 5.2μ CMD aerosols, equivalent added! sanitary ventilation of 39 ch/hr and 18 ch/hr were produced, respectively; these values are meaningful improvements in sanitary ventilation.
6