Neurosurgery · 2015 · 104 citations · 23 references
MedicineNeurosurgerySurgeryCerebrovascular NeurosurgeryCerebrovascular SurgeryVascular SurgeryAneurysm SurgeryCarotid Artery SurgeryCerebrovascular DiseaseNeurovascular AssessmentDevice EmbolizationEmbolization ImagingEndovascular EmbolizationGiant Aneurysm TreatmentIntracranial Aneurysm ImagingMiddle Cerebral Artery Aneurysm SurgeryResidual Aneurysm Neck
BACKGROUND: Utilization of the Pipeline embolization device (PED) to treat distal carotid circulation aneurysms has not been well studied. OBJECTIVE: To report the collective experience of using PED to treat distal anterior circulation aneurysms. METHODS: We retrospectively reviewed clinical and radiographic records of all patients who underwent Pipeline embolization of distal anterior circulation aneurysms at 10 US neurosurgical centers between 2011 and 2013. RESULTS: Twenty-eight patients (mean age 51.7 years; 18 women) with 28 aneurysms were included in the analyses. Fifteen aneurysms were fusiform, 5 dissecting, and 8 saccular. Average aneurysm size was 12.3 mm; 7 were giant. Twenty aneurysms were located along the middle cerebral artery, 6 along the anterior cerebral artery, and 2 along the anterior communicating artery. PED deployment was successful in 27 patients, with coils utilized in 6 cases. Clinical follow-up was available for an average of 10.7 months (range 3-26). Twenty-seven patients had follow-up neurovascular imaging: 21 aneurysms had complete occlusion, 4 had residual neck filling, and 2 had residual dome filling. Periprocedural complications (<30 days) occurred in 3 patients (10.7%), including 1 case of device failure resulting in stroke. Outcomes were good (modified Rankin Scale score 0 to 2) in 27 patients (96.4%) and fair (modified Rankin Scale 3) in 1. CONCLUSION: PED can be utilized in the treatment of distal anterior circulation aneurysms with difficult anatomy for conventional surgical or endovascular techniques. Larger-scale studies with long-term follow-up are needed to further elucidate the durability of PED treatment and its effect on perforator-rich vascular segments. ABBREVIATIONS: ACA, anterior cerebral arteryAcomA, anterior communicating arteryDSA, digital subtraction angiographyMCA, middle cerebral arterymRS, modified Rankin scalePED, Pipeline embolization device.
23
Jean Raymond, F Guilbert, Alain Weill et al. · Stroke · 2003 · 1.5K citations · Full text
Medicine, Neurosurgery, Surgery +9
Pipeline for Uncoilable or Failed Aneurysms: Results from a Multicenter Clinical Trial
Tibor Becske, David F. Kallmes, Cameron G. McDougall et al. · Radiology · 2013 · 1.1K citations · Full text
Medicine, Neurosurgery, Surgery +17
Endovascular Treatment of Unruptured Aneurysms
Daniel Roy, Geneviève Milot, Jean Raymond · Stroke · 2001 · 961 citations · Full text
Medicine, Neurosurgery, Surgery +17
The Pipeline Embolization Device for the Intracranial Treatment of Aneurysms Trial
Peter K. Nelson, Pedro Lylyk, István Szikora et al. · American Journal of Neuroradiology · 2010 · 837 citations · Full text
Medicine, Neurosurgery, Surgery +12
CURATIVE ENDOVASCULAR RECONSTRUCTION OF CEREBRAL ANEURYSMS WITH THE PIPELINE EMBOLIZATION DEVICE
Pedro Lylyk, Carlos Miranda, Rosana Ceratto et al. · Neurosurgery · 2009 · 803 citations
Medicine, Neurosurgery, Surgery +14