Behavior of aluminum in aluminum welders and manufacturers of aluminum sulfate—impact on biological monitoring

Vesa Riihimäki, Sinikka Valkonen, Berndt Engström, Antti Tossavainen, Pertti Mutanen, Antero Aitio

Scandinavian Journal of Work Environment & Health · 2008 · 25 citations · 12 references

DOIFull text

Open access

Concepts

Abstract

OBJECTIVES: The suitability of determining aluminum in serum or urine as a form of biological monitoring was critically assessed. METHODS: Airborne and internal aluminum exposure was assessed for 12 aluminum welders in a shipyard and 5 manufacturers of aluminum sulfate. Particles were characterized with X-ray diffraction and scanning electron microscopy. Aluminum in air and biological samples was analyzed using electrothermal atomic absorption spectrometry. Basic toxicokinetic features were inferred from the data. RESULTS: The mean 8-hour time-weighted average concentration of aluminum was 1.1 (range 0.008-6.1) mg/m(3) for the shipyard and 0.13 (range 0.02-0.5) mg/m(3) for the aluminum sulfate plant. Welding fume contained aluminum oxide particles <0.1 microm in diameter and their agglomerates, whereas bauxite and aluminum sulfate particles ranged from 1 to 10 microm in diameter. The shipyard welders' mean postshift serum and urinary concentrations of aluminum (S-Al and U-Al, respectively) were 0.22 and 3.4 micromol/l, respectively, and the aluminum sulfate workers' corresponding values were 0.13 and 0.58 micromol/l. Between two shifts, the welders' S-Al concentration decreased by about 50% (P<0.01), but their U-Al concentration did not change (P=0.64). No corresponding temporal changes occurred among the aluminum sulfate workers. After aluminum welding at the shipyard had ceased, the median S-Al concentration decreased by about 50% (P=0.007) within a year, but there was no change (P=0.75) in the corresponding U-Al concentration. CONCLUSIONS: About 1% of aluminum in welding fume appears to be rapidly absorbed from the lungs, whereas an undetermined fraction is retained and forms a lung burden. A higher fractional absorption of aluminum seems possible for aluminum sulfate workers without evidence of a lung burden. After rapid absorption, aluminum is slowly mobilized from the lung burden and dominates the S-Al and U-Al concentrations of aluminum welders. For kinetic reasons, S-Al or U-Al concentrations cannot be used to estimate the accumulation of aluminum in the target organs of toxicity. However, using U-Al analysis to monitor aluminum welders' lung burden seems practical.

References

12