Therapeutic Drug Monitoring · 2013 · 40 citations · 21 references
MedicineInfectious DiseasesPharmaceutical AnalysisDialysisHemodialysisRenal Replacement TherapyContinuous Renal Replacement TherapyCritical Care Therapeutic Drug MonitoringPharmacokinetics In Critical IllnessColistin Susceptibility TestingContinuous Veno-venous HemodiafiltrationMultidrug-resistant Gram-negative BacteriaResistance Mechanisms In Gram-negative BacteriaTherapeutic Dose RangeWhole Blood Concentration Assays
BACKGROUND: Colistin is a 50-year-old antibiotic, the use of which was ceased in the 70s and recently resumed as a "salvage therapy" against multidrug-resistant gram-negative bacteria, such as Pseudomonas aeruginosa and Acinetobacter baumannii. The narrow therapeutic range of colistin makes the choice of its correct dosage crucial, and monitoring of blood concentration is occasionally necessary for critically ill patients, including intensive care patients subjected to continuous renal replacement therapy. METHODS: Two LC-MS/MS methods were developed and fully validated for the quantitative determination of colistins A and B in plasma and dialysis ultrafiltrate (UF) samples, ultimately arising from 4 patients undergoing continuous venovenous hemodiafiltration (CVVHDF). RESULTS: The developed methods proved to be both specific and selective. They showed good fit and linearity over the entire range of interest. Trueness and accuracy proved satisfactory. Both methods have excellent intraassay precision (percent coefficient of variations were lower than 10%) and limit of detection values in the range 20-100 ng/mL, about 1-2 orders of magnitude below the concentrations commonly detected in real samples. The mean sieving coefficient (SC) values, measured after 10 minutes of CVVHDF, were 0.42 for colistin A and 0.48 for colistin B. SC values proved to be quite stable for 24 hours, but then declined to 0.24 for colistin A and 0.32 for colistin B, respectively, after 48 hours. At the median blood flow and effluent flow rate of 120 and 28 mL/min, clearance values for colistin B were higher than 15 mL/min. During the entire duration of CVVHDF sessions, the SC and clearance values for colistin A were significantly lower than colistin B. CONCLUSIONS: Two simple methods for the simultaneous determination of colistins A and B have been developed and validated. Their application in the clinical setting demonstrates that CVVHDF treatment lasting 48 hours produces a relatively constant and efficient removal of the drug.
21
Samira M. Garonzik, Jian Li, Visanu Thamlikitkul et al. · Antimicrobial Agents and Chemotherapy · 2011 · 685 citations · Full text
Diamantis Plachouras, Matti Karvanen, Lena E. Friberg et al. · Antimicrobial Agents and Chemotherapy · 2009 · 489 citations · Full text
Adverse Effects of Sodium Colistimethate
Jan Koch‐Weser · Annals of Internal Medicine · 1970 · 440 citations
Ami Fazlin Syed Mohamed, Ilias Karaiskos, Diamantis Plachouras et al. · Antimicrobial Agents and Chemotherapy · 2012 · 228 citations · Full text