Physical Review A · 2012 · 116 citations · 78 references
Natural SciencesChemistryPhysicsInstrumentationOpticsSpectroscopyAbsorption SpectroscopyAtomic Absorption SpectroscopyAtomic SpectroscopyLaser SpectroscopyOptical SpectroscopyPrecision SpectroscopyAbsorption Line SpectroscopyAbsorption SpectraAtomic Line ShapesAtomic Line SpectraCavity Ring-down SpectroscopyOptical Absorption LinesSpectral Line Shape AnalysisSpectral Line Shapes
An experiment enabling extremely high signal-to-noise ratios in the measurement of spectral line shapes is described. This approach, which combines high-bandwidth locking of a continuous wave probe laser and the frequency-stabilized cavity ring-down spectroscopy technique, enables long-term signal averaging and yields high-resolution spectra with a relatively wide dynamic range and low detection limit. By probing rovibronic transitions of the ${}^{16}$O${}_{2}$ $B$ band near $\ensuremath{\lambda}=689$ nm, exceptionally precise measurements of absorption line shape and line position are demonstrated. A signal-to-noise ratio of $220\phantom{\rule{0.16em}{0ex}}000$ and a minimum detectable absorption coefficient of $2.4\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}11}\phantom{\rule{4pt}{0ex}}{\mathrm{cm}}^{\ensuremath{-}1}$ is reported, which corresponds to the lowest line intensity measurable by this setup of approximately $1.3\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}30}\phantom{\rule{4pt}{0ex}}{\mathrm{cm}}^{\ensuremath{-}1}/(\mathrm{molecule}$ ${\mathrm{cm}}^{\ensuremath{-}2})$. Careful analysis of the data revealed a subtle line-shape asymmetry that could be explained by the speed dependence of the collisional shift. The demonstrated measurement precision enables the quantification of systematic line-shape deviations, which were approximately 1 part in 80 000 of the peak absorption. The influence of slowly drifting etaloning effects on the precision of the line-shape analysis is discussed. How this method can enable experiments that address a number of fundamental physical problems including the accurate optical measurement of the Boltzmann constant and tests of the symmetrization postulate is also discussed.
78
Laser phase and frequency stabilization using an optical resonator
R. W. P. Drever, J. L. Hall, Frank V. Kowalski et al. · Applied Physics B · 1983 · 3.8K citations
Natural Sciences, Physics, Optics +15
Statistics of atomic frequency standards
D.W. Allan · Proceedings of the IEEE · 1966 · 2.7K citations
The Effect of Collisions upon the Doppler Width of Spectral Lines
R. H. Dicke · Physical Review · 1953 · 1.5K citations