Is Trimellitic Anhydride Skin Testing a Sufficient Screening Tool for Selectively Identifying TMA-Exposed Workers With TMA-Specific Serum IgE Antibodies?

Jonathan A. Bernstein, Debajyoti Ghosh, Wesley J. Sublett, Heather Wells, Linda Levin

Journal of Occupational and Environmental Medicine · 2011 · 13 citations · 19 references

Concepts

Abstract

OBJECTIVE: Trimellitic anhydride (TMA) can elicit specific IgE-mediated immune responses leading to asthma. This single-blinded study investigated the ability of TMA skin testing to identify workers with TMA-serum specific IgE antibodies. METHODS: Forty TMA-exposed workers who were previously screened for the presence of TMA-IgG and/or IgE serum specific antibodies were skin tested to a TMA-human serum albumin reagent by nurses blinded to their antibody responses. RESULTS: Findings from skin-prick tests were positive in 8 of 11 workers with TMA-serum specific IgE antibodies. Intracutaneous testing, performed only on skin prick testing-negative workers, was positive in two additional workers with TMA-serum specific IgE antibodies. A significant correlation was found between serum and skin test dilutions eliciting positive responses (ρ = 0.87, P < 0.05; n = 11). CONCLUSIONS: TMA skin testing provides an alternative and potentially more practical method for monitoring TMA-exposed workers for developing IgE sensitization.

References

19