Canadian Journal of Neurological Sciences / Journal Canadien des Sciences Neurologiques · 2010 · 18 citations · 16 references
MedicineRadiologyDiagnostic ImagingDiagnostic RadiologyVascular SurgeryCarotid Artery DiseaseCerebrovascular DiseaseVascular ImagingArterial Stenosis AssessmentAutomated MeasurementCarotid Artery StenosisComputed Tomography AngiographyInterobserver ReproducibilityPearson Correlation CoefficientRecall BiasVascular Stenosis Assessment
PURPOSE: To compare the reproducibility of semi-automated vessel analysis software to manual measurement of carotid artery stenosis on computed tomography angiography (CTA). METHODS: Two observers separately analyzed 81 carotid artery CTAs using semi-automated vessel analysis software according to a blinded protocol. The software measured the narrowest stenosis in millimeters (mm), distal internal carotid artery (ICA) in mm, and calculated percent stenosis based on NASCET criteria. One observer performed this task twice on each carotid, the second analysis delayed two months in order to mitigate recall bias. Two other observers manually measured the narrowest stenosis in mm, distal ICA in mm, and calculated NASCET percent stenosis in a blinded fashion. Correlation coefficients were calculated for each group comparing the narrowest stenosis in mm, distal ICA in mm, and NASCET percent stenosis. RESULTS: The semi-automated vessel analysis software provided excellent intraobserver correlation for narrowest stenosis in mm, distal ICA in mm, and NACSET percent stenosis (Pearson correlation coefficients of 0.985, 0.954, and 0.977 respectively). The semi-automated vessel analysis software provided excellent interobserver correlation (0.925, 0.881, and 0.892 respectively). The interobserver correlation for manual measurement was good (0.595, 0.625, and 0.555 respectively). There was a statistically significant difference in the interobserver correlation between the semi-automated vessel analysis software observers and the manual measurement observers (P < 0.001). CONCLUSION: Semi-automated vessel analysis software is a highly reproducible method of quantifying carotid artery stenosis on CTA. In this study, semi-automated vessel analysis software determination of carotid stenosis was shown to be more reproducible than manual measurement.
16
CT Angiography for the Detection and Characterization of Carotid Artery Bifurcation Disease
Glenn B. Anderson, Rob Ashforth, David E. Steinke et al. · Stroke · 2000 · 212 citations · Full text
Quantification of carotid stenosis on CT angiography.
Eric Bartlett, Thomas D. Walters, Sean Symons et al. · PubMed · 2006 · 196 citations · Full text
Identification, prognosis, and management of patients with carotid artery near occlusion.
Allan J. Fox, Michael Eliasziw, Peter M. Rothwell et al. · PubMed · 2005 · 194 citations · Full text
Medicine, Neurosurgery, Surgery +9