Radiation Oncology · 2016 · 13 citations · 28 references
MedicineNuclear MedicineRadiation OncologyDiagnostic ImagingRadiation DosimetryTreatment PlanningComputed TomographyExternal Beam RadiotherapyIntensity-modulated RadiotherapyRadiation TherapyRadiation Treatment PlanningTreatment Planning Dose CalculationAdaptive Dose CalculationAdaptive Dose EscalationDeformable RegistrationImage-guided Intensity-modulated RadiotherapyIntensity-modulated Beam ArrangementIntensity-modulated Radiation Therapy DosimetryIntensity-modulated Radiotherapy Dose PrescriptionStatic Beam Intensity-modulated Radiotherapy
BACKGROUND: This study investigates the implementation of a new intensity modulated arc therapy (IMAT) class solution in comparison to a 6-static beam step-and-shoot intensity modulated radiotherapy (s-IMRT) for three-phase adaptive (18)F-FDG-PET-voxel-based dose-painting-by-numbers (DPBN) for head-and-neck cancer. METHODS: We developed (18)F-FDG-PET-voxel intensity-based IMAT employing multiple arcs and compared it to clinically used s-IMRT DPBN. Three IMAT plans using (18)F-FDG-PET/CT acquired before treatment (phase I), after 8 fractions (phase II) and CT acquired after 18 fractions (phase III) were generated for each of 10 patients treated with 3 s-IMRT plans based on the same image sets. Based on deformable image registration (ABAS, version 0.41, Elekta CMS Software, Maryland Heights, MO), doses of the 3 plans were summed on the pretreatment CT using validated in-house developed software. Dosimetric indices in targets and organs-at-risk (OARs), biologic conformity of treatment plans set at ≤5 %, treatment quality and efficiency were compared between IMAT and s-IMRT for the whole group and for individual patients. RESULTS: Doses to most organs-at-risk (OARs) were significantly better in IMAT plans, while target levels were similar for both types of plans. On average, IMAT ipsilateral and contralateral parotid mean doses were 14.0 % (p = 0.001) and 12.7 % (p < 0.001) lower, respectively. Pharyngeal constrictors D50% levels were similar or reduced with up to 54.9 % for IMAT compared to s-IMRT for individual patient cases. IMAT significantly improved biologic conformity by 2.1 % for treatment phases I and II. 3D phantom measurements reported an agreement of ≥95 % for 3 % and 3 mm criteria for both treatment modalities. IMAT delivery time was significantly shortened on average by 41.1 %. CONCLUSIONS: IMAT implementation significantly improved the biologic conformity as compared to s-IMRT in adaptive dose-escalated DPBN treatments. The better OAR sparing and faster delivery highly improved the treatment efficiency.
28
A technique for the quantitative evaluation of dose distributions
Daniel A. Low, William B. Harms, Sasa Mutic et al. · Medical Physics · 1998 · 2.9K citations · Full text
Christopher M. Nutting, James P. Morden, Kevin J. Harrington et al. · The Lancet Oncology · 2011 · 1.7K citations · Full text
Wilko F.A.R. Verbakel, J.P. Cuijpers, D. Hoffmans et al. · International Journal of Radiation Oncology*Biology*Physics · 2009 · 447 citations