Heart Rhythm · 2016 · 161 citations · 21 references
MedicineCardiologyHealth InformaticsBiomedical Signal ProcessingClinical CardiologyInterventional CardiologyAtrial FibrillationCardiac AssessmentCardiovascular MonitoringElectrocardiographyPatient MonitoringSignal DetectionAtrial Fibrillation DetectionAtrial Fibrillation MonitoringCardiac Monitoring SystemsDiagnostic Performance MetricsPatient MonitorsRemote Cardiac MonitoringRemote Patient MonitoringRemote Patient Monitoring Systems
BackgroundFor clinicians, confidence in atrial fibrillation (AF) episode classification is an important consideration when electing to use insertable cardiac monitors (ICMs).ObjectiveThe purpose of this study was to report on the improved AF detection algorithm in the Reveal LINQ ICM.MethodsThe Reveal LINQ Usability Study is a nonrandomized, prospective, multicenter trial. The ICM has been miniaturized, uses wireless telemetry for remote patient monitoring, and its AF algorithm includes a new p-wave filter. At 1 month post-device insertion, Holter monitor data were collected and annotated for true AF episodes ≥2 minutes, and performance metrics were evaluated by comparing Holter annotations with ICM detections.ResultsThe study enrolled 151 patients (age 56.6 ± 12.1, male 67%). Reasons for monitoring included AF ablation or AF management in 81.5% (n = 123), syncope in 12.6% (n = 19), and other indications in 5.9% (n = 9) of patients. Of the 138 patients with an analyzable Holter recording, a total of 112 true AF episodes were identified in 38 patients (27.5%). The overall accuracy of the ICM to detect durations of AF or non-AF episodes was 99.4%, and the AF burden measured by the ICM was highly correlated with the Holter (Pearson coefficient 0.995).ConclusionThe new AF detection algorithm in the Reveal LINQ ICM accurately detects the presence or absence of AF. Additionally, it showed high sensitivity in detecting AF duration in patients with a history of intermittent and symptomatic AF. For clinicians, confidence in atrial fibrillation (AF) episode classification is an important consideration when electing to use insertable cardiac monitors (ICMs). The purpose of this study was to report on the improved AF detection algorithm in the Reveal LINQ ICM. The Reveal LINQ Usability Study is a nonrandomized, prospective, multicenter trial. The ICM has been miniaturized, uses wireless telemetry for remote patient monitoring, and its AF algorithm includes a new p-wave filter. At 1 month post-device insertion, Holter monitor data were collected and annotated for true AF episodes ≥2 minutes, and performance metrics were evaluated by comparing Holter annotations with ICM detections. The study enrolled 151 patients (age 56.6 ± 12.1, male 67%). Reasons for monitoring included AF ablation or AF management in 81.5% (n = 123), syncope in 12.6% (n = 19), and other indications in 5.9% (n = 9) of patients. Of the 138 patients with an analyzable Holter recording, a total of 112 true AF episodes were identified in 38 patients (27.5%). The overall accuracy of the ICM to detect durations of AF or non-AF episodes was 99.4%, and the AF burden measured by the ICM was highly correlated with the Holter (Pearson coefficient 0.995). The new AF detection algorithm in the Reveal LINQ ICM accurately detects the presence or absence of AF. Additionally, it showed high sensitivity in detecting AF duration in patients with a history of intermittent and symptomatic AF.
21
2012 focused update of the ESC Guidelines for the management of atrial fibrillation
A. John Camm, Gregory Y.H. Lip, Raffaele De Caterina et al. · EP Europace · 2012 · 3.8K citations · Full text
Cryptogenic Stroke and Underlying Atrial Fibrillation
Tommaso Sanna, Hans‐Christoph Diener, Rod Passman et al. · New England Journal of Medicine · 2014 · 2.1K citations · Full text
Medicine, Cardiology, Neurology +17
Subclinical Atrial Fibrillation and the Risk of Stroke
Jeff S. Healey, Stuart J. Connolly, Michael R. Gold et al. · New England Journal of Medicine · 2012 · 2.1K citations · Full text
Atrial High Rate Episodes Detected by Pacemaker Diagnostics Predict Death and Stroke
Taya V. Glotzer, Anne S. Hellkamp, John Zimmerman et al. · Circulation · 2003 · 753 citations · Full text