Otolaryngology · 1992 · 41 citations · 17 references
MedicineSpeech-language PathologySurgeryEndocrine SurgeryImplant SurgeryLaryngologyLaryngeal ReconstructionLaryngeal SurgeryVocal Fold ParalysisVoice DisordersVoice RehabilitationVoice SurgeryPost-thyroidectomy Vocal Fold ParalysisPostoperative Voice AssessmentPreoperative Laryngeal AssessmentVocal Fold AugmentationVocal Fold MedializationVocal Pitch MonitoringVoice QualityVoice Quality Evaluation
This study investigated changes in voice quality after thyroplasty type I in eight adults with unilateral vocal fold paralysis. A silicone rubber implant was inserted through a window in the thyroid ala and placed between the inner and outer perichondrium to externally medialize the abducted vocal fold. Measures of fundamental frequency (vocal pitch), pitch range, maximum phonation time, s/z ratio, pitch perturbation (vocal jitter), and amplitude perturbation (vocal shimmer) were made 1 to 2 weeks preoperatively and 1 month postoperatively. Postoperative voice quality was characterized by an improved pitch range, phonation time, s/z ratio, and pitch and amplitude perturbation. No change was noted in fundamental frequency. Changes in postoperative voice quality were unrelated to the subjects' preoperative age, sex, etiology, and duration of the paralysis.
17
Journal of Communication Disorders · 1972 · 750 citations
Medicine, Speech-language Pathology, Aural Rehabilitation +9
Videostroboscopic evaluation of the larynx.
Diane M. Bless, Mayumi Hirano, Robert J. Feder · PubMed · 1987 · 233 citations
Laryngoplasty for vocal cord medialization: An Alternative To Teflon®
James A. Koufman · The Laryngoscope · 1986 · 211 citations
Medicine, Otolaryngology, Surgery +15