The “plateau effect” of cis‐platinum‐induced hearing loss

Steven F. Myers, Brian W. Blakley, Sabina Schwan, William F. Rintelmann, Robert H. Mathog

Otolaryngology · 1991 · 18 citations · 12 references

Concepts

Abstract

Cis-platinum-induced hearing loss has been reported to exhibit a "plateau effect" over the 2 to 8 kHz range. We examined serial audiometry data from 27 patients treated with cis-platinum. Although a plateau at 60 to 70 dB HL often occurred, this hearing loss was clearly exceeded in a number of patients. We identified 14 patients with sufficient cis-platinum-induced sensorineural hearing loss to evaluate a plateau limit to hearing loss over the 4 to 8 kHz range. Half of these 14 patients had hearing losses that exceeded the plateau level. More severe 4 to 8 kHz hearing losses did not correlate with number of treatments, cumulative dosages of cis-platinum, pre-existing hearing loss, radiation therapy, other chemotherapeutic agents, or even hearing losses below 4 kHz. Although cis-platinum therapy can induce a plateau of moderate hearing impairment for some patients over the 4 to 8 kHz range, a significant proportion of patients will experience more severe hearing impairment in this range, even after only one or two courses of cis-platinum.

References

12