Surgically-induced Astigmatism After Laser in situ Keratomileusis for Spherical Myopia

D. Huang, F. Seffo, David M. Meisler, R.R. Krueger

Journal of Refractive Surgery · 2000 · 27 citations · 3 references

Concepts

Abstract

PURPOSE: To characterize the surgically-induced-astigmatism (SIA) associated with spherical LASIK. METHODS: Refractive outcomes in 70 eyes that underwent primary myopic LASIK with purely spherical ablation were analyzed. The Summit Apex Plus excimer laser was used. The Bausch & Lomb Hansatome with the 180-microm plate was used to produce superiorly hinged flaps. The relationship between refractive astigmatism and corneal topographic astigmatism was analyzed using linear regression and vector analysis. RESULTS: There was a statistically significant negative correlation (slope = -0.21) between refractive surgically-induced astigmatism and preoperative topographic cylinder. A 0.24-D with-the-rule shift was also found. Surgically-induced astigmatism was not correlated with the magnitude of laser ablation. CONCLUSION: The lamellar keratotomy portion of LASIK reduces pre-existing corneal astigmatism and produces a relative steepening of the hinge meridian.

References