Ozone Science and Engineering · 1994 · 32 citations · 5 references
Natural SciencesChemistryEnvironmental SciencesAnalytical ChemistryChromatographic AnalysisEnvironmental ChemistryAnalytical ChromatographyChromatographyEnvironmental AnalysisEnvironmental Analytical ChemistryOzone ChemistryWater ChemistryDetection Limit AnalysisDetection Limit AssessmentDetection Limit EstimationInterferenceLinear RangeMethod Detection LimitOzone
A flow injection, non-ion chromatographic method has been developed using chlorpromazine for the determination of bromate ion in ozone treated waters containing bromide ion. The procedure has been automated over a linear operating range of 1.0 to 30.0 μ/L The precision of the method in reagent water is calculated to be better than 2.5% with an accuracy within ± 1 μ/L The method detection limit (MDL) is 0.8 μ/L. Chemical masks are described to minimize potential interference from nitrite ion and chlorite ion.
5
Trace analyses for wastewaters
John A. Glaser, Denis L. Foerst, Gerald D. McKee et al. · Environmental Science & Technology · 1981 · 447 citations
Natural Sciences, Environmental Engineering, Environmental Sciences +17