PLoS ONE · 2015 · 24 citations · 23 references
MedicineCardiologyPediatricsClinical CardiologyPediatric CardiologyPediatric RadiologyCongenital Heart DiseaseCongenital Heart Disease ImagingPediatric Cardiac SurgeryPediatric EchocardiographySeptal DefectsCardiac Malformation AssessmentCardiac Malformation EvaluationDouble-outlet Right Ventricle ImagingIntracardiac EchocardiographySeptal Defect DiagnosisVentricular Septal Defect AssessmentVentricular Septal Defect EvaluationVentricular Septal Defect Imaging
PURPOSE: To evaluate the feasibility and diagnostic accuracy of retrospective electrocardiographically (ECG)-gated dual-source computed tomography (DSCT) for the assessment of double outlet right ventricle (DORV) and associated multiple malformations in pediatric patients. MATERIALS AND METHODS: Forty-seven patients <10 years of age with DORV underwent retrospective ECG-gated DSCT. The location of the ventricular septal defect (VSD), alignment of the two great arteries, and associated malformations were assessed. The feasibility of retrospective ECG-gated DSCT in pediatric patients was assessed, the image quality of DSCT and the agreement of the diagnosis of associated malformations between DSCT and transthoracic echocardiography (TTE) were evaluated, the diagnostic accuracies of DSCT and TTE were referred to surgical results, and the effective doses were calculated. RESULTS: Apart from DORV, 109 associated malformations were confirmed postoperatively. There was excellent agreement (κ = 0.90) for the diagnosis of associated malformations between DSCT and TTE. However, DSCT was superior to TTE in demonstrating paracardiac anomalies (sensitivity, coronary artery anomalies: 100% vs. 80.00%, anomalies of great vessels: 100% vs. 88.57%, separate thoracic and abdominal anomalies: 100% vs. 76.92%, respectively). Combined with TTE, DSCT can achieve excellent diagnostic performance in intracardiac anomalies (sensitivity, 91.30% vs. 100%). The mean image quality score was 3.70 ± 0.46 (κ = 0.76). The estimated mean effective dose was < 1 mSv (0.88 ± 0.34 mSv). CONCLUSIONS: Retrospective ECG-gated DSCT is a better diagnostic tool than TTE for pediatric patients with complex congenital heart disease such as DORV. Combined with TTE, it may reduce or even obviate the use of invasive cardiac catheterization, and thus expose the patients to a much lower radiation dose.
23
Preface, Executive Summary and Glossary
Annals of the ICRP · 2007 · 2.1K citations
First performance evaluation of a dual-source CT (DSCT) system
Thomas Flohr, Cynthia H. McCollough, Herbert Bruder et al. · European Radiology · 2005 · 1.4K citations
Benefits and costs, an eternal balance
Adrian K. Dixon · Annals of the ICRP · 2007 · 1.4K citations
Wyman W. Lai, Tal Geva, Girish Shirali et al. · Journal of the American Society of Echocardiography · 2006 · 894 citations
Medicine, Pediatrics, Radiology +12