Physics in Medicine and Biology · 2016 · 10 citations · 33 references
EngineeringComputer ScienceNuclear EngineeringDiagnostic ImagingNuclear InstrumentationRadiation DetectionRadiation Imaging DetectorsRadiation Imaging SystemsScintillation DetectorsCrystal IdentificationDetectorsGaussian Mixture ModelsPosition-sensitive DetectorsScintillationScintillation DetectionScintillator CrystalsThin Plate Spline
A typical positron emission tomography detector is comprised of a scintillator crystal array coupled to a photodetector array or other position sensitive detector. Such detectors using light sharing to read out crystal elements require the creation of a crystal lookup table (CLUT) that maps the detector response to the crystal of interaction based on the x-y position of the event calculated through Anger-type logic. It is vital for system performance that these CLUTs be accurate so that the location of events can be accurately identified and so that crystal-specific corrections, such as energy windowing or time alignment, can be applied. While using manual segmentation of the flood image to create the CLUT is a simple and reliable approach, it is both tedious and time consuming for systems with large numbers of crystal elements. In this work we describe the development of an automated algorithm for CLUT generation that uses a Gaussian mixture model paired with thin plate splines (TPS) to iteratively fit a crystal layout template that includes the crystal numbering pattern. Starting from a region of stability, Gaussians are individually fit to data corresponding to crystal locations while simultaneously updating a TPS for predicting future Gaussian locations at the edge of a region of interest that grows as individual Gaussians converge to crystal locations. The algorithm was tested with flood image data collected from 16 detector modules, each consisting of a 409 crystal dual-layer offset LYSO crystal array readout by a 32 pixel SiPM array. For these detector flood images, depending on user defined input parameters, the algorithm runtime ranged between 17.5-82.5 s per detector on a single core of an Intel i7 processor. The method maintained an accuracy above 99.8% across all tests, with the majority of errors being localized to error prone corner regions. This method can be easily extended for use with other detector types through adjustment of the initial template model used.
33
Simultaneous PET-MRI: a new approach for functional and morphological imaging
Martin S. Judenhofer, Hans F. Wehrl, D.F. Newport et al. · Nature Medicine · 2008 · 978 citations
The Multivariate Normal Distribution
Alan Julian Izenman, Y. L. Tong · Technometrics · 1991 · 669 citations