Photomedicine and Laser Surgery · 2015 · 29 citations · 31 references
DentistryEndodonticsOral BiologyBiophotonicsEndodontic MicrobiologyRoot Canal TherapyBiomedical Laser ApplicationsLaser-tissue InteractionRoot CariesBactericidal AgentsCaries Affected DentinDental Laser ApplicationsEnterococcus Faecalis ControlEnterococcus Faecalis In EndodonticsLaser Irradiation ParametersOral Bacterial Load ReductionRoot Dentin Peritubular Dentin
OBJECTIVE: The aim of this in vitro study was to investigate the antibacterial effect of the dual wavelength (2780 nm Er,Cr:YSGG and 940 nm diode) laser in elimination of Enterococcus faecalis in comparison with a 2780 nm Er,Cr:YSGG laser alone. BACKGROUND DATA: Various laser wavelengths have been introduced as an adjunct in root canal treatment because of laser's bactericidal effect. MATERIALS AND METHODS: Seventy- five slices of dentin with thicknesses of 300, 500, and 1000 μm (n = 25 each) obtained from caries-free bovine teeth were inoculated with 1 μL of E. faecalis suspension [1.67 × 10(7) colony-forming units (CFU)] and divided randomly into three groups: (A) samples indirectly irradiated with power settings of 1.06 W, 50 Hz, and 50 μs for Er,Cr:YSGG laser; (B) samples indirectly irradiated with Er,Cr:YSGG laser with the same power settings as group A and simultaneously with a 940 nm diode laser of 0.51 W in pulsed mode; and five samples from each thickness that were chosen as an unirradiated control group (Co). After irradiation, the CFU of E. faecalis were counted and the bacterial reduction was analyzed using Kruskal-Wallis nonparametric and post-hoc Dunnett tests. RESULTS: There were statistical differences between groups A and B compared with the control group over all the three dentin slice thicknesses (p < 0.001). However, there was no statistical difference between groups A and B in killing of E. faecalis on 500 μm dentin slices. There were significantly more viable bacteria in group A than in group B in 300 and 1000 μm dentin slices (p < 0.01). CONCLUSIONS: The results of this in vitro study showed that the dual wavelength laser system obtained a significantly higher bactericidal effect on E. faecalis than Er,Cr:YSGG laser, reaching a depth of 1000 μm of dentin.
31
Prashant Nair, U. Sjögren, Gunthild Krey et al. · Journal of Endodontics · 1990 · 758 citations
Bacterial reduction with nickel-titanium rotary instrumentation
B. Clark Dalton, Dag Ørstavik, Ceib Phillips et al. · Journal of Endodontics · 1998 · 339 citations
Bactericidal effect of different laser systems in the deep layers of dentin
Ulrich Schoop, W. Kluger, Andreas Moritz et al. · Lasers in Surgery and Medicine · 2004 · 308 citations