Veterinary MedicinePathologyUrologyDiagnostic ImagingUltrasonographyUltrasoundDiagnostic UltrasonographyElastographyTesticular DisordersTesticular PathologyTesticular TraumaTesticular UltrasonographyBlood FlowElastic Modulus MeasurementNormal Tissue DelineationTesticular Mass CharacterizationTesticular Torsion AssessmentTesticular Torsion ImagingTesticular UltrasoundYoung's Modulus
Real-time shear-wave elastography (SWE) is a newly developed method which can obtain the stiffness of tissues and organs based on tracking of shear wave propagation through a structure. Several studies have demonstrated its potential in the differentiation between diseased and normal tissue in clinical practices, however the applicability to testicular disease has not been well elucidated. We investigated the feasibility and reproducibility of SWE in the detection of testicular torsion. This prospective study comprised 15 patients with complete testicular torsion. Results obtained from SWE along with conventional gray-scale and color Doppler sonography and post-operative pathology were compared. The results revealed that (i) the size of injured testis was increased and the twisted testis parenchyma was heterogeneous. The blood flow signals in injured testis were barely visible or absent; (ii) The Young's modulus, including Emean, Emax, Emin and SD values in the border area of torsional testis were higher than those of normal testis (Emean, 78.07±9.01 kPa vs 22.0±5.10 kPa; Emax, 94.07±6.53 kPa vs 27.87±5.78 kPa; Emin, 60.73±7.84 kPa vs 18.90±4.39 kPa; SD, 7.67±0.60 kPa vs 2.30±0.36 kPa, [P<0.05]); The Emax and SD values in the central area of the torsional testis were higher than the corresponding area of the normal testis (Emax, 8.23±0.30 kPa vs 3.97±0.95 kPa; SD, 1.5±0.26 kPa vs 0.67±0.35 kPa,[P<0.05]) and Emin values was lower than those of normal testicles (0.93±0.51 kPa vs 1.6±0.36 kPa; [P<0.05]); (iii) The Young's modulus measurement between two physicians showed good agreement. The pathological findings were accordance with SWE measurement. SWE is a non-invasive, convenient and high reproducible method and may serve as an important alternative tool in the diagnosis and monitoring the progression of the acute scrotums, in additional to conventional Doppler sonography.
37
Elastography: A Quantitative Method for Imaging the Elasticity of Biological Tissues
J. Ophir, I. Céspedes, H. Ponnekanti et al. · Ultrasonic Imaging · 1991 · 3.5K citations
Breast Disease: Clinical Application of US Elastography for Diagnosis
Ako Itoh, Ei Ueno, Eriko Tohno et al. · Radiology · 2006 · 1.6K citations
Quantifying Hepatic Shear Modulus In Vivo Using Acoustic Radiation Force
Mark L. Palmeri, M.H. Wang, Jeremy Dahl et al. · Ultrasound in Medicine & Biology · 2008 · 683 citations · Full text
Natural Sciences, Physics, Radiology +14