Advanced Functional Materials · 2015 · 469 citations · 31 references
EngineeringBioengineeringBiomedical EngineeringBiomedical Signal ProcessingBiosensorsSensorsBiomedical SensorsCardiovascular MonitoringElectrocardiographyMedical InstrumentationWearable BiosensorsWearable Health TechnologiesBlood PressureBlood Pressure MeasurementBlood Pressure MonitoringContinuous MonitoringCuffless Blood Pressure MeasurementPiezoresistive SensingPower ConsumptionSensor Sensitivity
Cuffless blood‑pressure monitoring offers unobtrusive, continuous measurement essential for diagnosing and preventing hypertension‑related cardiovascular disease. The authors present a wearable patch that combines a flexible piezoresistive sensor with epidermal ECG electrodes to measure blood pressure, emphasizing a trade‑off between sensor sensitivity and signal stability. They develop parametric models of the piezoresistive sensor’s response and optimize operating conditions to create a stable epidermal pulse monitor, enabling beat‑to‑beat blood‑pressure estimation from ECG and pulse signals. Compared with optical cuffless devices, the patch consumes only 3 nW and detects subtle physiological changes such as pre‑ and post‑exercise variations, offering a low‑power, real‑time, home‑based monitoring solution.
Noninvasive and real‐time cuffless blood pressure (BP) measurement realizes the idea of unobtrusive and continuous BP monitoring which is essential for diagnosis and prevention of cardiovascular diseases associated with hypertension. In this paper, a wearable sensor patch system that integrates flexible piezoresistive sensor (FPS) and epidermal electrocardiogram (ECG) sensors for cuffless BP measurement is presented. By developing parametric models on the FPS sensing mechanism and optimizing operational conditions, a highly stable epidermal pulse monitoring method is established and beat‐to‐beat BP measurement from the ECG and epidermal pulse signals is demonstrated. In particular, this study highlights the compromise between sensor sensitivity and signal stability. As compared with the current optical‐based cuffless BP measurement devices, the sensing patch requires much lower power consumption (3 nW) and is capable of detecting subtle physiological signal variations, e.g., pre and postexercises, thus providing a promising solution for low‐power, real‐time, and home‐based BP monitoring.
31
Ultrasensitive mechanical crack-based sensor inspired by the spider sensory system
Daeshik Kang, Peter V. Pikhitsa, Yong Whan Choi et al. · Nature · 2014 · 1.6K citations