Global Journal of Obesity Diabetes and Metabolic Syndrome · 2014 · 36 citations · 19 references
MedicineBiochemistryClinical BiochemistryPulmonary Function TestingPulmonologyDiabetic KetoacidosisMetabolic EvaluationPulmonary Function AssessmentRespiratory AssessmentBreath Analysis MethodologyBreath Biomarker DetectionKetone MeasurementKetonesLipid Oxidation MarkersNutritional KetosisRespiratory Quotient AnalysisVapor Pressure
Former ketone studies, including ketoacidosis (KAD), fasting ketosis (FK), nutritional ketosis (NK), and exercis-eaffected ketosis have brought great advances to the field of ketones. In the present work, blood, urine and breath ketone detections were evaluated systematically. We found that breath ketone (acetone) is the ketone of choice for detecting early stages of ketosis. In addition, acetone was correlated with respiratory quotient, and found to be a highly sensitive non-invasive biomarker of lipid oxidation. Furthermore, acetone was used for fast screening of ketosis or ketoacidosis in populations, and demonstrated value upon screening a population of 48 individuals, among which a type I diabetes case with early symptoms of KAD and FK case were identified.
19
Bonnie J. Brehm, Randy J. Seeley, Stephen R. Daniels et al. · The Journal of Clinical Endocrinology & Metabolism · 2003 · 834 citations
Medical aspects of ketone body metabolism.
Grant A. Mitchell, Sacha Kassovska‐Bratinova, Youssef Boukaftane et al. · PubMed · 1995 · 259 citations
Chuji Wang, Armstrong Mbi, Mark D. Shepherd · IEEE Sensors Journal · 2009 · 230 citations