Comparative Study of RCC and Composite Multistoreyed Buildings

S. V. Itti

2013 · 11 citations · 3 references

Concepts

Abstract

Steel concrete composite construction means the concrete slab is connected to the steel beam with the help of shear connectors so that they act as a single unit. In the present work steel concrete composite with RCC options are considered for comparative study of B+G+15 storey of residential building which is situated in earthquake zone 3 and for earthquake loading, the provisions of IS:1893(Part1)-2002 is considered. For modeling of composite and RCC structures, STAAD-proV8i software is used. The results of this work shows that, the cost of composite beam is less by 27% as compared to RCC beam. The maximum shear force and maximum bending moment are less in composite beam as compared to RCC beam. The node displacement is on higher side in composite structure as compared to RCC structure. The weight of composite structure is also less compared to RCC structure. Composite structures are the best solution for high rise structure as compared to RCC structure.

References

3