Deposition of Bloody Friction Ridge Impressions

Glenn Langenburg

2008 · 26 citations · 2 references

Concepts

Abstract

To date, no experiments have been published measuring the cause and effect relationship of various deposition factors and the resultant appearance of the ridge detail in a bloody friction ridge impression. This study reports the effects of deposition pressure (at four categories of pressure: light, medium, heavy, and extreme), the effects of increasing volumes of human blood loaded onto a finger (from 10 µL to 100 µL), the effects of depositing impressions on a horizontal surface versus a vertical surface, and finally, the effects of allowing the blood to dry on the finger for a significant amount of time before depositing the impression (hereafter: predeposition wait- ing interval or PWI). Prior to testing these variables, a series of study design tests were also performed to optimize the conditions of the study. During these tests, we examined several other factors (such as the temperature of the blood, the ambient air temperature, the tem- perature of the skin) for their contribution to the appearance of the bloody impressions. The trials showed that to produce identifiable impressions, rel- atively small amounts of blood were needed (10 to 20 µL). When impressions were deposited in a vertical position, increasing the deposition pressure produced more impressions of evidential value. Identifiable impressions were produced with larger volumes of blood when there was a significant PWI interval. After allowing some of the excess blood to dry on the finger, an identifiable impression was deposited.

References

2