A WIRE POSITION MONITOR SYSTEM FOR THE ISAC-II CRYOMODULE COMPONENTS ALIGNMENT

W. R. Rawnsley, Y. Bylinski, G. Dutto, K. Fong, Robert Laxdal, T. Ries, D. Giove

2004 · 12 citations · 3 references

Concepts

Abstract

TRIUMF is developing ISAC-II, a superconducting (SC) linac. It will comprise 9 cryomodules with a total of 48 niobium cavities and 12 SC solenoids. They must remain aligned at liquid He temperatures: cavities to ±400 µm and solenoids to ±200 µm after a vertical contraction of ~4 mm. A wire position monitor (WPM) system based on a TESLA design has been developed, built, and tested with a prototype cryomodule. The system is based on the measurement of signals induced in pickups by a 215 MHz signal carried by a wire through the WPMs. The wire is stretched between the warm tank walls parallel to the beam axis providing a position reference. The sensors, one per cavity and two per solenoid, are attached to the cold elements to monitor their motion during pre-alignment, pumping and cool down. A WPM consists of four 50 Ω striplines spaced 90° apart. A GaAs multiplexer scans the WPMs and a Bergoz card converts the rf signals to dc X and Y voltages. National Instruments I/O cards read the dc signals. The data acquisition is based on a PC running LabVIEW. System accuracy is ~7 µm. The paper describes system design, WPM calibration and test results.

References

3