2014 · 15 citations · 16 references
DentistryBioengineeringPeriodonticsCraniofacial RegenerationOral Tissue RegenerationTissue EngineeringBiomaterials For Oral RegenerationFibrin FormationPlatelet ActivationPlatelet FunctionPlatelet PhysiologyCentrifugation ParametersCraniofacial Tissue RegenerationFibrin Clot ArchitectureFibrin Mechanical PropertiesFibrin NetworksGrowth FactorsPlatelet-rich Fibrin TherapyTissue Regeneration
Background and Objectives. Platelet concentrates for surgical use (Platelet-Rich Plasma PRP or Platelet-rich fibrin PRF) are surgical adjuvants to improve healing and promote tissue regeneration. L-PRF (Leukocyte- and Platelet-Rich Fibrin) is one of the 4 families of platelet concentrates for surgical use and is widely used in oral and maxillofacial regenerative therapies. The objective of this first article was to evaluate the mechanical vibrations appearing during centrifugation in 4 models of commercially available table centrifuges frequently used to produce L-PRF. Materials and Methods. The 4 different tested centrifuges were the original L-PRF centrifuge (Intra-Spin, Intra-Lock, the only CE and FDA cleared system for the preparation of L-PRF) and 3 other laboratory centrifuges (not CE nor FDA cleared for L-PRF): A-PRF 12 (Advanced PRF, Process), LW - UPD8 (LW Scientific) and Salvin 1310 (Salvin Dental). Each centrifuge was opened for inspection, two accelerometers were installed (one radial, one vertical), and data were collected with a spectrum analyzer. Each centrifuge was tested in 2 configurations (full-load or half load with 9ml blood collection tubes filled with water) and at the following rotational speeds: 1500, 1800, 2100, 2400, 2700, 3000 and 3300 rpm. Extra rotational speeds were used on some centrifuges. One centrifuge (Salvin) had only one available rotational speed (3400 rpm). For each test, the software documented both radial and vertical vibration. Results. Very significant differences in the level of vibrations at each rotational speed were observed between the 4 tested machines. The original L-PRF centrifuge (Intra-Spin) was by far the most stable machine in all configurations. At the classical speed of production of LPRF, the level of undesirable vibration on this centrifuge is between 4.5 and 6 times lower
16
David M. Dohan Ehrenfest, Giuseppe Maria de Peppo, Pierre Doglioli et al. · Growth Factors · 2008 · 589 citations
Medicine, Bioengineering, Hematology +16
David M. Dohan Ehrenfest, Matthias A. Zumstein, Changqing Zhang et al. · PubMed · 2014 · 420 citations · Full text
Sofia Aroca, Tibor Keglevich, Bruno Barbieri et al. · Journal of Periodontology · 2009 · 380 citations
Ziv Mazor, Robert Horowitz, Marco Del Corso et al. · Journal of Periodontology · 2009 · 350 citations
Dentistry, Oral Surgery, Surgery +16