EngineeringElectrical EngineeringBiomedical ImagingMicroelectronicsSemiconductor DevicesElectron MicroscopyIntegrated Circuit DesignIntegrated Circuit DevicesIntegrated Circuit FabricationIntegrated OpticsX-ray OpticsCurrent ImagingHigh-resolution X-ray ImagingMicroscopyMicroscopy ImagingScanning Electron MicroscopyX-ray Imaging OpticsX-ray Imaging PhysicsX-ray Lithography
We introduce x-ray microscopy as a method for imaging integrated circuits. Compared to physical de- layering combined with scanning electron microscopy, this method is non-destructive, requiring only sample thinning to approximately 100 um but otherwise leaving the sample intact. Using multiple views and 3D tomography, individual integrated circuit layers can be imaged. Current imaging resolution is approximately 30 nm, and is constantly improving with advances in nano-fabrication for hard x-ray optics.