1999 IEEE Nuclear Science Symposium. Conference Record. 1999 Nuclear Science Symposium and Medical Imaging Conference (Cat. No.99CH37019) · 2003 · 56 citations · 15 references
MedicineNuclear MedicineRadiologyBiomedical ImagingDiagnostic ImagingDigital ImagingBayesian ComputationBrain ImagingImage ReconstructionMonte Carlo MethodsMonte Carlo SimulationCovarianceCovariance Matrix ApproximationObserver Performance EvaluationOperating ConditionsPet Image ReconstructionReconstruction AlgorithmsTomographic QuantificationTomographic Reconstruction
We describe a method for computing linear observer statistics for maximum a posteriori (MAP) reconstructions of PET images. The method is based on a theoretical approximation for the mean and covariance of MAP reconstructions. In particular, we derive here a closed form for the channelized Hotelling observer (CHO) statistic applied to 2D MAP images. We show reasonably good correspondence between these theoretical results and Monte Carlo studies. The accuracy and low computational cost of the approximation allow us to analyze the observer performance over a wide range of operating conditions and parameter settings for the MAP reconstruction algorithm.
15
3-D phantom to simulate cerebral blood flow and metabolic images for PET
E.J. Hoffman, Paul Cutler, W.M. Digby et al. · IEEE Transactions on Nuclear Science · 1990 · 356 citations