Artificial Organs · 2015 · 10 citations · 26 references
MedicineInternal MedicineNephrologyDialysisHemodialysisRenal Replacement TherapyChronic HemodialysisHemodynamicsMaintenance HemodialysisRenal Blood FlowRenal Function TestsRenal HemodynamicsCardiac OutputCardiac Output ChangesHemodynamic MonitoringHemodynamic Response MonitoringHemodynamic Response To UltrafiltrationRelative Blood Volume ChangesRelative Blood Volume MonitoringUltrafiltration
Hemodialysis (HD) is usually performed with the gradually decreasing ultrafiltration rate (UFR) profile (dUFR). The aim of the present study was to compare the hemodynamic response to HD with the dUFR to that of HD with the gradually increasing UFR profile (iUFR). The study population included 10 patients (three women, mean age: 28 ± 8 years) undergoing maintenance HD who had reached dry weight without taking antihypertensive medications. Each patient received (in random order) one HD session with the dUFR and another with the iUFR (both with 3 h total UFR = 2200 mL). Hemodynamic response was evaluated with a brachial blood pressure (BP) monitor, echocardiogram and Portapres to measure digital BP, heart rate, cardiac output, stroke volume, and peripheral resistance. Mean values were compared at each HD hour during the first 3 h of a 4-h HD session. The HD characteristics, including Kt/V, were similar for both UFR profiles. Relative blood volume decreased more gradually and linearly with the iUFR. Hemodynamic variables were not significantly different between the two profiles, but brachial BP was more stable with the iUFR. Digital diastolic BP increased with both profiles. Peripheral resistance increased with both profiles, and tended to increase more with the iUFR. Echocardiographic variables changed similarly during the HD session with both profiles. In conclusion, these two UFR profiles are similar in most hemodynamic variables. The statistical equivalence of both profiles suggests that either could be prescribed based on the clinical characteristics of the patient.
26
James O. Burton, Helen J. Jefferies, Nicholas M. Selby et al. · Clinical Journal of the American Society of Nephrology · 2009 · 416 citations · Full text
EBPG guideline on haemodynamic instability
Jeroen P. Kooman, Francesco Pizzarelli, Bernard Canaud et al. · Nephrology Dialysis Transplantation · 2007 · 293 citations · Full text
Noninvasive Assessment of the Digital Volume Pulse
Sandrine Millasseau, Franck G. Guigui, Ronan P. Kelly et al. · Hypertension · 2000 · 291 citations · Full text
Engineering, Cardiology, Physiology +15