Magazine of Concrete Research · 2015 · 40 citations · 17 references
EngineeringCivil EngineeringMaterials EngineeringStructural AnalysisStructural EngineeringStructural MaterialsBending Of BeamsComposite MaterialsConcrete ConstructionConcrete MaterialsConcrete TechnologyReinforced Concrete StructuresAbsorption CapacityCementitious CompositesEnergy AbsorptionEngineered Cementitious CompositesForce Absorption CapacityReinforced ConcreteReinforcementShear Behavior
The study presents test results of 12 reinforced concrete beams with varying shear span‑to‑depth ratios and longitudinal reinforcement amounts to compare engineered cementitious composite and normal concrete behavior. Twelve beams were tested, split into two groups of six, with engineered cementitious composite and normal concrete, each with three shear span‑to‑depth ratios and two reinforcement levels. ECC beams exhibited superior shear behavior, with higher strength, stiffness, ductility, and energy absorption than normal concrete beams, though the advantage varied with shear span‑to‑depth ratio.
This paper presents test results of 12 reinforced concrete beams having three shear span to depth ratios and two different amounts of main longitudinal reinforcement. The test specimens were divided into two similar groups – the first six beams were made from engineered cementitious composites (ECCs), whereas the other six beams were made using normal concrete (NC). The test results showed that the behaviour of ECC beams under shear is, overall, much better than that of NC beams. The strength, stiffness, ductility and energy absorption capacity of the ECC beams were found to be significantly higher than those of the corresponding NC beams. However, these comparisons depend on the shear span to depth ratio.
17