IEEE Transactions on Biomedical Engineering · 2013 · 52 citations · 17 references
MedicineBiomedical EngineeringUrologyDiagnostic ImagingUltrasonographyUltrasoundImage-guided BiopsyImage-guided InterventionProstate BiopsyRobotic UltrasoundSurgical RoboticsUltrasound-guided ProceduresMedical Ultrasound ProbesProstate Biopsy DiagnosisProstate Cancer DiagnosisRobotic Biopsy GuidanceTransrectal Ultrasound-guided BiopsyUltrasound Guidance AccuracyUltrasound Probe CalibrationUltrasound Probe Manipulation
Image-to-robot registration is a typical step for robotic image-guided interventions. If the imaging device uses a portable imaging probe that is held by a robot, this registration is constant and has been commonly named probe calibration. The same applies to probes tracked by a position measurement device. We report a calibration method for 2-D ultrasound probes using robotic manipulation and a planar calibration rig. Moreover, a needle guide that is attached to the probe is also calibrated for ultrasound-guided needle targeting. The method is applied to a transrectal ultrasound (TRUS) probe for robot-assisted prostate biopsy. Validation experiments include TRUS-guided needle targeting accuracy tests. This paper outlines the entire process from the calibration to image-guided targeting. Freehand TRUS-guided prostate biopsy is the primary method of diagnosing prostate cancer, with over 1.2 million procedures performed annually in the U.S. alone. However, freehand biopsy is a highly challenging procedure with subjective quality control. As such, biopsy devices are emerging to assist the physician. Here, we present a method that uses robotic TRUS manipulation. A 2-D TRUS probe is supported by a 4-degree-of-freedom robot. The robot performs ultrasound scanning, enabling 3-D reconstructions. Based on the images, the robot orients a needle guide on target for biopsy. The biopsy is acquired manually through the guide. In vitro tests showed that the 3-D images were geometrically accurate, and an image-based needle targeting accuracy was 1.55 mm. These validate the probe calibration presented and the overall robotic system for needle targeting. Targeting accuracy is sufficient for targeting small, clinically significant prostatic cancer lesions, but actual in vivo targeting will include additional error components that will have to be determined.
17
Rebecca L. Siegel, Deepa Naishadham, Ahmedin Jemal · CA A Cancer Journal for Clinicians · 2012 · 10.7K citations · Full text
Rapid calibration for 3-D freehand ultrasound
Richard W. Prager, Robert Rohling, Andrew H. Gee et al. · Ultrasound in Medicine & Biology · 1998 · 386 citations
Mechanically assisted 3D ultrasound guided prostate biopsy system
Jeffrey Bax, Derek W. Cool, Lori Gardi et al. · Medical Physics · 2008 · 140 citations
Tissue mimicking materials for a multi‐imaging modality prostate phantom
Ernest L. Madsen, Orhan Ünal, Karl K. Vigen et al. · Medical Physics · 2001 · 108 citations · Full text
Medicine, Bioengineering, Radiology +17