Spectroscopy and laser oscillation properties of lithium neodymium tetraphosphate

Kenju Otsuka, Tomoaki Yamada, M. Saruwatari, T. Kimura

IEEE Journal of Quantum Electronics · 1975 · 83 citations · 18 references

Concepts

Abstract

Optical absorption, fluorescence, and laser characteristics of lithium neodymium tetraphosphate (LiNdP <inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">4</inf> O <inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">12</inf> , abbreviated as LNP) were examined. The crystal belongs to the monoclinic system (pseudoorthorhombic system) and the Nd content is <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">4.37 \times 10^{21}</tex> cm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-3</sup> . The lifetime of the <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">4</sup> <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">F_{3/2}</tex> level is 120 μs, which is one-half of 230μs observed in Nd:YAG. The largest effective emission cross section at the line peak ( <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1.047_{7} \mu</tex> m) was spectroscopically determined as <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3.2 \times 10^{-19}</tex> cm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> for the electric vector parallel to the pseudoorthorhombic <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">c</tex> axis and quantum efficiency was estimated as 0.48. Quasi-continuous laser oscillation pumped by a chopped Ar-ion laser was achieved with a 1.85-mm-long crystal. The output light was linearly polarized along the pseudoorthorhombic <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">c</tex> axis of the crystal, which does not depend on the polarization direction of the pump light. The measured threshold and round-trip loss yield the value of <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3.1 \times 10^{-19}</tex> cm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> for the effective emission cross section of LNP, which is in good agreement with the value obtained from the spectroscopic data.

References

18