Daehan saengsik uihak hoeji/Clinical and experimental reproductive medicine · 2011 · 53 citations · 35 references
Veterinary MedicineGeneticsInfertilityReproductive BiologyReproductive MedicineMale InfertilitySemen AnalysisSperm Dna Integrity AssessmentSperm Morphology AssessmentSperm Motility AssessmentSperm Viability AssessmentComet Assay ScoringHuman Sperm MorphologyHuman Sperm Viability TestingNeutral Comet AssaySperm Chromatin Integrity AssessmentSperm Dna DamageSperm Dna Fragmentation AssessmentSperm Quality Abnormalities
OBJECTIVE: To explore potential relationships between sperm DNA integrity and both semen parameters and clinical outcomes. METHODS: Semen analysis of 498 samples was performed according to the 2010 criteria of the World Health Organization. The sperm DNA fragmentation Index (DFI) of the semen samples was assessed using a neutral comet assay. RESULTS: Sperm DFI showed a significant correlation with semen parameters, including the patient's age, sperm viability, motility, morphology, and number of leukocytes (p<0.05). The sperm DFI values for asthenozoospermic (15.2%), oligoteratozoospermic (18.3%), asthenoteratozoospermic (17.5%), and oligoasthenoteratozoospermic semen samples (21.3%) were significantly higher than that observed in normozoospermic semen samples (10.5%, p<0.05). A sperm DFI value of 14% was used as a threshold of sperm DFI in assessing whether DNA was highly damaged. In 114 IVF-ET cycles, the fertilization rate of the sperm DFI <14% group (70 cycles, 61.7%) was significantly higher than that observed for the ≥14% group (44 cycles, 55.3%), but there was no difference in the other clinical outcomes between the two groups. In the ≥14% group, the pregnancy rates of the ICSI cycles (40.0%) and half-ICSI (44.0%) were higher than conventional IVF cycles (30.7%), but the difference was not statistically significant. CONCLUSION: Along with the conventional semen analysis, the sperm DFI assessed using the comet assay was shown to improve the quality of the semen evaluation. To evaluate the precise effect of ICSI on pregnancy rates in the patients who demonstrate high sperm DFI values, further study is necessary.
35
Intracytoplasmic Sperm Injection May Increase the Risk of Imprinting Defects
Gerald F. Cox, Joachim Bürger, Va Lip et al. · The American Journal of Human Genetics · 2002 · 705 citations · Full text
Medicine, Gynecology, Obstetrics +14
Sperm DNA integrity assessment in prediction of assisted reproduction technology outcome
M. Bungum, Peter Humaidan, Anna Axmon et al. · Human Reproduction · 2006 · 697 citations · Full text
Michael R. Virro, Kjersten L. Larson-Cook, Donald P. Evenson · Fertility and Sterility · 2004 · 597 citations · Full text