Nucleic Acids Research · 2000 · 795 citations · 20 references
Life SciencesGeneticsMolecular BiologyGenomicsNucleic Acid BiochemistryNucleic Acid ChemistryNucleic Acid Amplification TestingPolymerase Chain ReactionBase Pair MismatchesDna ProbesFluorescence QuenchingMelting TemperatureNucleic Acid Hybridization AssaysNucleic Acid ProbesProbe SpecificityReal-time Polymerase Chain Reaction (Pcr)
DNA probes with conjugated minor groove binder (MGB) groups form extremely stable duplexes with single‑stranded DNA targets, enabling the use of shorter probes in hybridization assays. The study explored the sequence specificity of 3'-MGB probes and developed fluorogenic MGB probes for use in 5'-nuclease real‑time PCR assays. The authors synthesized fluorogenic 3'-MGB probes and evaluated them in 5'-nuclease real‑time PCR assays. MGB probes exhibited higher melting temperatures and superior specificity for single‑base mismatches, with 12‑mer probes matching the Tm of 27‑mer unmodified probes, efficient fluorescence quenching, and improved sensitivity, while A/T‑rich duplexes were more stabilized than G/C‑rich duplexes, leveling Tm and simplifying design.
DNA probes with conjugated minor groove binder (MGB) groups form extremely stable duplexes with single-stranded DNA targets, allowing shorter probes to be used for hybridization based assays. In this paper, sequence specificity of 3'-MGB probes was explored. In comparison with unmodified DNA, MGB probes had higher melting temperature (T(m)) and increased specificity, especially when a mismatch was in the MGB region of the duplex. To exploit these properties, fluorogenic MGB probes were prepared and investigated in the 5'-nuclease PCR assay (real-time PCR assay, TaqMan assay). A 12mer MGB probe had the same T(m)(65 degrees C) as a no-MGB 27mer probe. The fluorogenic MGB probes were more specific for single base mismatches and fluorescence quenching was more efficient, giving increased sensitivity. A/T rich duplexes were stabilized more than G/C rich duplexes, thereby leveling probe T(m)and simplifying design. In summary, MGB probes were more sequence specific than standard DNA probes, especially for single base mismatches at elevated hybridization temperatures.
20
S P Colowick, M D Joshi, Jagannathan et al. · 1966 · 26.2K citations
Pamela M. Holland, Richard D. Abramson, R. R. Watson et al. · Proceedings of the National Academy of Sciences · 1991 · 2.7K citations
Kenneth J. Livak, Samantha Flood, J Marmaro et al. · Genome Research · 1995 · 1.6K citations · Full text
Multicolor molecular beacons for allele discrimination
Sanjay Tyagi, Diana P. Bratu, Fred Russell Kramer · Nature Biotechnology · 1998 · 1.3K citations