Acta Orthopaedica Scandinavica · 1986 · 48 citations · 27 references
Veterinary MedicineOrthopaedic SurgeryOrthopedic SurgeryHeavy Metal ToxicologyMetallic MaterialsMetallurgyChromium ToxicologyCobalt ToxicityCobalt ToxicologyHeavy Metal AnalysisHeavy Metal ContaminationMetal ToxicityBlood Cobalt LevelsBlood Heavy Metal LevelsMetal HypersensitivitySkin Sensitivity ReactionsUrinary Cobalt LevelsUrinary Heavy Metal AnalysisUrinary Metal BiomarkersUrine Heavy Metal Levels
We measured levels of metal ions in urine and plasma of 17 patients 7-15 years after they had a Co-Cr-Mo alloy total hip replacement. They had higher levels of cobalt and chromium than controls. No case of skin sensitivity to the investigated metals was observed. The values of cobalt and chromium in plasma and urine were considerably lower than in professionally exposed groups and do not represent a toxic hazard for the patients.
27
Incidence of metal sensitivity in patients with total joint replacements.
M. W. Elves, James N. Wilson, John T. Scales et al. · BMJ · 1975 · 255 citations · Full text
Metal sensitivity in patients with joint replacement arthroplasties.
Michael Benson, P G Goodwin, J Brostoff · BMJ · 1975 · 210 citations · Full text