British Journal of Urology · 1982 · 11 citations · 6 references
MedicineUrologyNeurourologyUrodynamicsVoiding DysfunctionBladder Function AssessmentDetrusor-sphincter DyssynergiaSpinal Cord InjuryUrethral FunctionUrinary IncontinenceUrodynamic EvaluationDetrusor DyssynergiaLower Urinary Tract ObstructionProfilometrySpinal Cord Injury - Associated DyssynergiaSpinal Cord LesionsUrethral ElectromyographyUrethral Pressure DynamicsUrodynamic Pressure Measurement
Forty-two spinal injury patients underwent single or sequential urodynamic studies to assess the value of dynamic urethral pressure using transducer tipped catheters. Three groups of patients were identified: those with poor detrusor function, those with unsustained dyssynergia and those with sustained dyssynergia. All patients demonstrated some dyssynergia. Urethral needle EMG mirrored urethral pressure changes accurately. The addition of dynamic profilometry to fluoroscopy, detrusor pressure and urethral EMG has clarified our understanding of lower urinary tract behaviour after cord lesions.
6
Detrusor-Sphincter Dyssynergia
Edward J. McGuire, Susan Brady · The Journal of Urology · 1979 · 106 citations
Urodynamics in Spinal Shock Patients
Alain B. Rossier, Bushra A. Fam, Margarete DiBenedetto et al. · The Journal of Urology · 1979 · 43 citations
Medicine, Urology, Neurourology +13