Comparative Inactivation of <i>Bacillus subtilis</i> Spores Using a DBD-Driven Xenon Iodide Excilamp and a Conventional Mercury Lamp

Takashi Kamikozawa, Hisayoshi Kurokawa, Hideki Motomura, Kazunori Kadowaki, Masafumi Jinno

IEEE Transactions on Plasma Science · 2010 · 18 citations · 13 references

Concepts

Abstract

In this paper, we compared the inactivation of <i xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">Bacillus subtilis</i> spores in water by means of a dielectric-barrier-discharge (DBD)-driven XeI* excilamp and a low-pressure mercury lamp. The main part ( ~ 76%) of the excilamp output was due to the <i xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">B</i> → <i xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">X</i> transition of XeI* exciplex at 253 nm. It is shown for the first time that a better sterilization action is achieved with the DBD-driven XeI* excilamp compared with the monochromatic mercury lamp at the same UV dose. The contribution of an atomic iodine emission in the range of 178-207 nm has been confirmed. Germ-reduction experiments with the XeI* excilamp have been carried out in a steady-state mode and in a water-flow reactor.

References

13