Bell System Technical Journal · 1978 · 22 citations · 11 references
Health ProfessionsAudiologyPhoneticsPhonologyPsychoacousticsSpeech IntelligibilitySpeech Intelligibility EnhancementSpeech Perception In NoiseSpeech Perception OutcomesSpeech RecognitionVoice ProcessingClarityCoder Performance EvaluationObjective EvaluationSpeech EnhancementSpeech Enhancement AlgorithmsSpeech Quality AssessmentSpeech Quality PerceptionSubjective Quality Assessment
An experiment has been performed to study the perceptual characteristics of speech processed by adaptive differential PCM. We created 18 three-bit and four-bit coders spanning a wide range of quantizer adaptation parameters. Subjects judged differences between coders and rated the quality of each coder individually. The difference data reveal three important perceptual characteristics: overall clarity, signal vs. background degradation, and rough vs. smooth impairment. These characteristics are strongly correlated with coder design parameters and objective performance measures. Overall subjective quality is well predicted by segmental signal-to-noise ratio and even better by a linear combination of measures of granular distortion and overload distortion.
11