International Journal of Audiology · 2012 · 36 citations · 11 references
Health ProfessionsAudiologyHearing ScienceOtologyPsychoacousticsHearing ImpairmentHearing LossHearing Protection DevicesNoiseNoise-induced Hearing DamageSound LocalizationElectronic EarmuffsHearing ProtectionHearing Protection Device EffectivenessHearing Protection EffectivenessLocalization In NoiseLocalization Performance AssessmentLocalization Performance EvaluationResponse Time
The study aimed to evaluate how different hearing protection‑enhancement devices affect the ability to localize gunshot sounds in a realistic field environment, compared to open ear and under heavy truck noise. A controlled field experiment measured five localization accuracy and response‑time metrics for eight shooter azimuth positions with nine normal‑hearing and four impaired‑hearing participants using four HPEDs and open‑ear conditions. The electronic earmuffs performed worse than other HPEDs and open ear in accuracy and response time, with no overall noise effect; hearing impairment increased right‑left confusions, and none of the HPEDs preserved normal localization.
Objective: A controlled field experiment was conducted to evaluate localization of suprathreshold gunshot reports (from blank cartridges) with four hearing protection-enhancement devices (HPEDs) in comparison to the open ear with ambient outdoor noise and in 82 dBA diesel military heavy truck noise. Design: Five measures of localization accuracy and response time for eight shooter positions in azimuth were measured. Study sample: Nine normal-hearing and four impaired-hearing participants were tested. Results: Statistical analysis showed worse accuracy and response time performance with the electronic earmuffs (Peltor Com-Tac II™ in full gain position) than with the other tested HPEDs (Etymotic EB 1 and EB 15 High-Fidelity Electronic BlastPLG™ electronic earplugs, both set to Lo gain positions; and 3M Single-Ended Combat Arms™ passive earplug in level-dependent, "open" position). Performance with all HPEDs was worse than that with the open ear, except on right-left confusions, in which the earmuff stood alone as worst, and in response time, for which the EB 1 was equivalent to the open ear. There was no significant main effect of noise on performance. Hearing impairment increased right-left confusions. Subjective ratings related to localization generally corroborated objective localization performance. Conclusions: None of the tested HPEDs preserved "normal" localization performance.
11
John G. Casali · The International Journal of Acoustics and Vibration · 2010 · 36 citations · Full text