IEEE Transactions on Dielectrics and Electrical Insulation · 2015 · 53 citations · 16 references
Natural SciencesMaterials EngineeringMaterials ScienceElectronic MaterialsMaterials CharacterizationMechanical Behavior Of MaterialsCurrent-voltage CharacteristicsDevice CharacterizationElectrical CharacterizationElectrical MetrologyErosionErosion AssessmentInclined PlanesInsulation Resistance TestingRound Robin TestingSheet Erosion AssessmentSilicone ElastomersSurface Erosion Assessment
The paper reviews previous work on the DC inclined plane test and suggests equivalent DC voltage levels in parallel to AC voltage in the ASTM inclined plane tracking and erosion test. The aim of this work is to provide a basis for standardizing the inclined plane test for DC voltage. Round robin tests done in five laboratories on five specimens of a silicone rubber material were done with the purpose of establishing appropriate ratios by which the equivalent DC voltages can be determined with respect to the corresponding AC voltages. These levels were determined as 67% and 87%, for +DC and -DC respectively, of the AC initial tracking voltage, and for practical purposes, these levels are rounded to 70 and 90%.
16
Mohammed El Amine Slama, Abderrahmane Béroual, H. Hadi · IEEE Transactions on Dielectrics and Electrical Insulation · 2010 · 86 citations