Closed-loop control impact on the diagnosis of induction motors faults

A. Bellini, F. Filippetti, G. Franceschini, C. Tassoni

IEEE Transactions on Industry Applications · 2000 · 198 citations · 15 references

DOIFull text

Open access

Concepts

Abstract

In this paper, the impact of control on faulted induction machine behavior is presented. The diagnostic indexes usually used for open-loop operation are no longer effective. Simulation and experimental results show that the spectrum of the field current component i/sub d/ in a field-oriented controlled machine has suitable features that can lead to an effective diagnostic procedure. Specifically, in the case of stator and rotor faults, the i/sub d/ spectrum components at frequencies 2f and 2sf, respectively, are quite independent of control parameters and dependent on the fault extent.

References