Stroke · 2015 · 125 citations · 23 references
MedicineSurgeryCerebrovascular SurgeryInterventional CardiologyVascular SurgeryCerebrovascular DiseaseStent PlacementStrokeCerebral Arterial StenosisCollaterals FormationIntracranial Arterial StentingIntracranial Atherosclerotic Disease InterventionIntracranial StentingPrimary Outcome AnalysisSelf-expanding StentsVascular Stenting
BACKGROUND AND PURPOSE: Although recent trials have suggested that stenting is worse than medical therapy for patients with severe symptomatic intracranial atherosclerotic stenosis, it is not clear whether this conclusion applies to a subset of patients with hypoperfusion symptoms. To justify for a new trial in China, we performed a multicenter prospective registry study to evaluate the safety and efficacy of endovascular stenting within 30 days for patients with severe symptomatic intracranial atherosclerotic stenosis. METHODS: Patients with symptomatic intracranial atherosclerotic stenosis caused by 70% to 99% stenosis combined with poor collaterals were enrolled. The patients were treated either with balloon-mounted stent or with balloon predilation plus self-expanding stent as determined by the operators following a guideline. The primary outcome within 30 days is stroke, transient ischemic attack, and death after stenting. The secondary outcome is successful revascularization. The baseline characteristics and outcomes of the 2 treatment groups were compared. RESULTS: From September 2013 to January 2015, among 354 consecutive patients, 300 patients (aged 58.3±9.78 years) were recruited, including 159 patients treated with balloon-mounted stent and 141 patients with balloon plus self-expanding stent. The 30-day rate of stroke, transient ischemic attack, and death was 4.3%. Successful revascularization was 97.3%. Patients treated with balloon-mounted stent were older, less likely to have middle cerebral artery lesions, more likely to have vertebral artery lesions, more likely to have Mori A lesions, less likely to have Mori C lesions, and likely to have lower degree of residual stenosis than patients treated with balloon plus self-expanding stent. CONCLUSIONS: The short-term safety and efficacy of endovascular stenting for patients with severe symptomatic intracranial atherosclerotic stenosis in China is acceptable. Balloon-mounted stent may have lower degree of residual stenosis than self-expanding stent. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT01968122.
23
Stenting versus Aggressive Medical Therapy for Intracranial Arterial Stenosis
Marc I. Chimowitz, Michael Lynn, Colin P. Derdeyn et al. · New England Journal of Medicine · 2011 · 1.9K citations · Full text
Medicine, Neurosurgery, Surgery +13
A standardized method for measuring intracranial arterial stenosis.
Owen Samuels, Gregg J. Joseph, Michael Lynn et al. · PubMed · 2000 · 968 citations · Full text