Journal of Hygiene · 1978 · 78 citations · 6 references
Life SciencesMicrobiologyBacteriologyEnvironmental MicrobiologyMedical MicrobiologyAir SamplingMicrobial ContaminationOperating Room Air Quality ControlOperating Room Environmental ControlAirborne Microbial TransportBacterial Contamination AssessmentFloor Contamination ControlIndoor Air Microbial AssessmentIndoor Air MicrobiologyMicrobial Control In FacilitiesMicrobial Dispersion In AirOperating Room Environmental Hygiene
The redispersal factor for bacteria-carrying particles from a contaminated floor was determined after mopping, blowing and walking activity. Walking gave the highest redispersal factor, 3.5 X 10(-3) m-1, which was three times higher than for blowing and 17 times higher than for mopping. The mean die-away rate for the bacteria-carrying particles used was 1.9/h without ventilation and 14.3/h with ventilation. It was calculated that in the operating rooms less than 15% of the bacteria found in the air were redispersed floor bacteria.
6
Ward floors and other surfaces as reservoirs of hospital infection
G.A.J. Ayliffe, Beverly Collins, E. J. L. Lowbury et al. · Epidemiology and Infection · 1967 · 137 citations · Full text
R. B. Bourdillon, O. M. Lldwell, E. Lovelockj. et al. · 1948 · 56 citations