Journal of Performance of Constructed Facilities · 2000 · 30 citations · 6 references
EngineeringArchitectural EngineeringCivil EngineeringConstruction EngineeringStructural AnalysisStructural EngineeringFailure AnalysisStructural Condition AssessmentStructural DesignStructural IntegrityStructural MechanicsStructural ReliabilityCollapse AssessmentCollapse LoadCollapse Mechanism AnalysisCollapse MechanismsInelastic Dynamic AnalysisProfessional Responsibility Of ExpertsProject WorkflowStructural Failure Analysis
Was the collapse of the Hyatt hotel atrium walkway a senseless tragedy or a steppingstone in the betterment of the engineering and scientific endeavor? The collapse claimed 114 lives, leading to a great public and professional outcry and having a dramatic impact on the careers and lives of many fine professionals. The architecture and engineering (A&E) community in the United States began a soul-searching debate on issues as diverse as how project workflow is managed to professional responsibility and ethics. Fundamental errors were identified in the project interaction within the A&E group as well as the construction industry. This review provides a presentation of the demand-capacity ratio within elements primary to the failure and presents results of detailed inelastic analysis of the box girder-to-hanger rod connection. The collapse occurred simply because of the doubling of the load on the connection resulting from an ill-considered change of an ill-defined structural detail. How this error was produced, and how any minor additional effort might have substantially improved the connection capacity, is addressed herein.
6