Clinical Chemistry · 1993 · 121 citations · 2 references
Life SciencesBiochemistryPharmacologyClinical BiochemistryElectroanalytical MethodsGood Laboratory PracticeBioanalytical Method ValidationHormone StorageCatecholamine BiochemistryCatecholamine StorageReagent Storage ConditionsUrine Sample CollectionUrine Sample Preservation
Improvements in methodologies for measuring concentrations of catecholamines (CA) have led to an increasing use of these compounds as markers in the screening of patients and in long-term clinical trials. Because of the associated logistical problems, we have investigated the unresolved question of optimal conditions for sample preparation and for storage of plasma and urine samples. Results show that blood should be centrifuged within 1 h after collection; the use of a refrigerated centrifuge is not necessary. Once plasma is prepared, CA are stable for 1 day at 20 degrees C, 2 days at 4 degrees C, 1 month at -20 degrees C (or 6 months with added glutathione), and up to 1 year at -70 degrees C. CA are stable at 4 degrees C for 1 month in unpreserved urine and for 4 months in urine preserved with EDTA and sodium metabisulfite. In acidified urine, CA were nearly unchanged after 1 year at 4 and -20 degrees C.
2
VALIDITY OF PLASMA-CATECHOLAMINE ESTIMATIONS
Malcolm Carruthers, Neville Conway, Peter Taggart et al. · The Lancet · 1970 · 140 citations