2002 · 54 citations · 5 references
EngineeringElectrical EngineeringElectric MachinesPower ElectronicsRenewable Energy SystemsGenerator OperationPower Electronics For Renewable EnergyPower QualityRenewable EnergyRenewable Energy Power ConversionWind Energy SystemsGenerator EfficiencyGeneratorsLinearizationPower Conversion For Wind Energy SystemsPower Conversion SystemsPower UtilityWind Energy Conversion SystemsWind Power Systems
Two methods of incorporating the variable-reluctance generator (VRG) into advanced wind conversion systems at or above the 50-kW power level are presented. Operating through a power electronic interface to the electric utility, this generator offers simplifications of the utility/generator interface over adjustable-speed wind conversion systems based on the induction generator. In addition, analyses performed using experimentally based data show that the VRG system is as much as 6% more efficient and up to 13% less expensive than a comparably rated induction generator system. These analyses are based on a piecewise linearization of the nonlinear VRG characteristics. At comparable power levels, the VRG can offer superior utility power-quality relative to the induction generator systems presently under development, and also offers a reduction in the operating, maintenance, and energy costs associated with advanced wind-energy systems.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">></ETX>
5
Variable-speed switched reluctance motors
P.J. Lawrenson, J.M. Stephenson, N.N. Fulton et al. · IEE Proceedings B Electric Power Applications · 1980 · 775 citations