Publication | Closed Access
SHEWMA: an end-of-line SPC scheme using wafer acceptance test data
25
Citations
16
References
2000
Year
End-of-line Spc SchemeEngineeringIndustrial EngineeringMeasurementDiagnosisComputer ArchitectureEducationWafer Acceptance TestWat DataNumerical DerivationsCondition MonitoringReliability EngineeringAdvanced Packaging (Semiconductors)Systems EngineeringModeling And SimulationElectronic PackagingInstrumentationTest BenchProcess MeasurementHardware-in-the-loop SimulationProcess MonitoringComputer EngineeringDesign For TestingSoftware TestingProcess ControlIndustrial InformaticsIndustrial Process Control
In this paper, an end-of-line quality control scheme based on wafer acceptance test (WAT) data is presented. Due to the multiple-stream and sequence-disorder effects typically present in the WAT data, an abnormal process shift caused by one machine at an in-line step may become vague for detection using end-of-line WAT data. A methodology for generating robust design parameters for the simultaneous application of Shewhart and EWMA control charts to WAT data is proposed. This SHEWMA scheme is implemented in a foundry environment and its detection and diagnosis-enhancing capabilities are validated using both numerical derivations and fab data. Results show that the SHEWMA scheme is superior to the current practices in detection speed. Its use is complementary to the existing in-line SPC for process integration.