The viscosity of acetone‐water solutions up to their normal boiling points

Katherine S. Howard, R. A. McAllister

AIChE Journal · 1958 · 35 citations · 7 references

DOIFull text

Open access

Concepts

Abstract

Abstract The viscosity of acetone‐water liquid solutions has been measured over the entire concentration range at temperatures from 20°C. to generally within 1° to 10°C. of the normal boiling point. A capillary suspended‐level viscometer was used, and the authors estimate that the results are accurate to ±0.2%. Both kinematic and absolute viscosities are given, and the results have been extrapolated to the boiling point of the solutions. The calibration of the Cannon‐Ubbelohde viscometer is discussed in detail.

References

7