2008 · 12 citations · 2 references
EngineeringElectrical EngineeringElectric MachinesFinite Element AnalysisFinite Element MethodsDevice CharacterizationElectric MotorsMagnetic CharacterizationMagnetic Circuit AnalysisNonlinear Finite Element AnalysisPermanent Magnet MachinesElectromagnetic Performance AnalysisFinite Element Analysis Of MachinesFinite Element Analysis Of Magnetic ComponentsInductance CalculationInductance MeasurementMagnetic FluxPermanent Magnet MotorsPermanent Magnet Synchronous Motors
We have developed a method that uses AC with a DC bias to measure the inductances (L <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">d</sub> , L <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">q</sub> ) of permanent magnet synchronous motors (PMSMs). Such motors are widely used in electrical equipment because they are highly efficient. Our method can be used to measure nonlinear characteristics of a PMSM, such as magnetic flux and inductance with cross-magnetization. We have compared our method with a conventional method and the results of a finite-element method analysis. The comparisons with the finite-element method analysis revealed that our method can be used to accurately determine the inductances of PMSMs, which is necessary in some vector control strategies.
2