Heart · 2007 · 33 citations · 19 references
Health ProfessionsEmergency Medical ServicesEmergency MedicineEmergency ManagementEmergency Medical DispatchResuscitationAmbulance OperationsCardiac Arrest DispatchCardiac Arrest ManagementCardiopulmonary ResuscitationEmergency TriagePriority DeterminationCardiac Arrest AlgorithmsCardiac Arrest EpidemiologyConcordance Between Death CertificatesEmergency Medical Dispatch Priority SystemsEmergency Medical Services DispatchOut-of-hospital Cardiac ArrestOut-of-hospital Cardiac Event IdentificationPublic Access Defibrillation
OBJECTIVES: To determine the diagnostic accuracy of advanced medical priority dispatch system (AMPDS) software used to dispatch public access defibrillation first responders to out-of-hospital cardiac arrests (OHCA). DESIGN: All true OHCA events in North and West Belfast in 2004 were prospectively collated. This was achieved by a comprehensive search of all manually completed Patient Report Forms compiled by paramedics, together with autopsy reports, death certificates and medical records. The dispatch coding of all emergency calls by AMPDS software was also obtained for the same time period and region, and a comparison was made between these two datasets. SETTING: A single urban ambulance control centre in Northern Ireland. POPULATION: All 238 individuals with a presumed or actual OHCA in the North and West Belfast Health and Social Services Trust population of 138 591 (2001 Census), as defined by the Utstein Criteria. MAIN OUTCOME MEASURES: The accurate dispatch of an emergency ambulance to a true OHCA. RESULTS: The sensitivity of the dispatch mechanism for detecting OHCA was 68.9% (115/167, 95% confidence interval (CI) 61.3% to 75.8%). However, the sensitivity for arrests with ventricular fibrillation (VF) was 44.4% (12/27) with sensitivity for witnessed VF of 47.1% (8/17). The positive predictive value was 63.5% (115/181, 95% CI 56.1% to 70.6%). CONCLUSIONS: The sensitivity of this dispatch process for cardiac arrest is moderate and will constrain the effectiveness of Public Access Defibrillation (PAD) schemes which utilise it. TRIAL REGISTRATION: controlled-trials.com ISRCTN07286796.
19
Ian Jacobs, Vinay Nadkarni, Jan Bahr et al. · Resuscitation · 2004 · 909 citations · Full text
Health Professions, Emergency Medical Services, Emergency Medicine +15
Public Use of Automated External Defibrillators
Sherry L. Caffrey, Paula J. Willoughby, Paul E. Pepe et al. · New England Journal of Medicine · 2002 · 802 citations · Full text