MedicineOtolaryngologySpeech-language PathologyLaryngologyMovement AnalysisPulmonologyLaryngeal AnatomyLaryngeal ImagingLaryngeal PhysiologyVocal Fold ParalysisVoice DisordersArytenoid DislocationArytenoid MovementInterrater AgreementInterrater ReliabilityLaryngeal ElectromyographyLaryngeal Motion AnalysisLaryngeal ParalysisRecurrent Laryngeal Nerve Paralysis
OBJECTIVE: To present a new method of quantifying arytenoid movement during inspiration and determine if it can be used to distinguish arytenoid dislocation from vocal fold paralysis. STUDY DESIGN: Case series with chart review. SETTING: Retrospective study conducted in a university laboratory based on university hospital data. SUBJECTS AND METHODS: Endoscopic videos from 8 patients with dislocation and 5 patients with vocal fold paralysis diagnosed by electromyography were included. Vector analysis measured cuneiform movement, an indirect measurement of arytenoid movement, during 1 inspiration. Measurements normalized and not normalized to vocal fold length were evaluated. Interrater reliability (2 raters) and intrarater reliability (1 rater performing the analysis twice) were evaluated using intraclass correlation coefficient (ICC) analysis. Raters were blinded to subject group during analysis. RESULTS: Pixel-valued cuneiform movement was 81.16 ± 25.62 for dislocation and 30.22 ± 23.60 for paralysis (P = .019). Unitless cuneiform movement was 0.58 ± 0.17 for dislocation and 0.24 ± 0.18 for paralysis (P = .030). Interrater ICC was 0.942 for pixel-valued measurements and 0.962 for unitless measurements. Intrarater ICC was 0.909 for pixel-valued measurements and 0.881 for unitless measurements. CONCLUSIONS: Both pixel-valued and unitless measures of arytenoid movement were significantly greater in arytenoid dislocation than vocal fold paralysis. Pixel-valued measurements were included to demonstrate the ability to make quantitative comparisons across subjects without precise knowledge of camera precision, provided position is approximately stable, as each measurement is inherently normalized by vocal tract length. Future studies will apply this new method of evaluating vocal fold immobility disorders on a larger scale and incorporate a more diverse group of etiologies.
13
Fast Normalized Cross-Correlation
Jae-Chern Yoo, Tae Hee Han · Circuits Systems and Signal Processing · 2009 · 1.1K citations
Laryngeal Synkinesis Revisited
Roger L. Crumley · Annals of Otology Rhinology & Laryngology · 2000 · 271 citations
Arytenoid Cartilage Dislocation: A 20-year Experience
Adam D. Rubin, Mary J. Hawkshaw, Cheryl A. Moyer et al. · Journal of Voice · 2005 · 130 citations
Michael C. Munin, Clark A. Rosen, Thomas G. Zullo · Archives of Physical Medicine and Rehabilitation · 2003 · 111 citations