Journal of Fire Protection Engineering · 2005 · 67 citations · 5 references
EngineeringBuilding ScienceCivil EngineeringBuilding MaterialsBuilding StructuresStructural EngineeringFire Hazard ReductionFire PreventionFire SafetyFire Safety EngineeringFire-resistant MaterialsStructural Fire EngineeringConcrete StrengthFire ResistanceFire-resistant ConcreteFire-resistant ConstructionHigh-strength Concrete
An overview of the research program, aimed at developing fire resistance design guidelines for high-strength concrete (HSC) columns, is outlined. A comparison is made of the fire resistance performance of an HSC column with that of a normal-strength concrete (NSC) column. The various factors that influence the structural behavior of HSC columns under fire conditions are discussed. Design guidelines are presented for mitigating spalling and enhancing fire endurance of HSC columns.
5
Limits of spalling of fire-exposed concrete
Kristian Dahl Hertz · Fire Safety Journal · 2003 · 518 citations
Building Code Requirements for Reinforced Concrete
ACI Committee · ACI Journal Proceedings · 1970 · 365 citations
Fire Endurance of High Strength Concrete Columns
Venkatesh Kodur, R. McGrath · Fire Technology · 2003 · 136 citations · Full text